KB Quality grade is Kinetic Blocks' own grade, A+ to F, measured from the files across four pillars: Technical, Temporal integrity, Content, Completeness. How grading works
A real residential electrical job, recorded first person: 2016x1520 colour, global-shutter stereo, depth and a 400 Hz head IMU. Both hands wear sensor gloves with 12 IMUs and 10 force pads each. Every frame has a 21-joint pose for both hands (MANO joint order, MANO-style joint rotations) and each hand's orientation in the camera; forearm AprilTags add the wrist position and 2D keypoints when in view. LeRobot v2.1.
Dataset card
# Electrician installing an outdoor conduit run and subpanel: head-mounted stereo egocentric video + depth, tactile sensor gloves on both hands (24 IMUs, 20 force pads, force in newtons) and 3D hand pose for both hands, placed in the camera by forearm AprilTags, 45:29 min, 38 labelled steps
## Summary
A real residential job, recorded first person on 3 November 2026 in Utah, USA: a master electrician opens the main panel, lays out and measures black feeder wires and a green ground along the side yard, tapes the wire ends, pushes them through an existing conduit stub and pulls them up into the main panel, unboxes a new subpanel, knocks out and fits a conduit adapter, cuts PVC conduit with a band saw and a ratchet cutter, cements and couples the conduit up the wall, levels and screws the subpanel to the wall, straps the conduit, connects the feeder wires in the subpanel and routes and strips them in the main panel. The recording stops mid-step at the main panel. The job is cut into 38 episodes, one per step, each with a plain-language step label in its task string.
The head camera is a Luxonis OAK-D Pro W worn on the head: colour camera, global-shutter stereo pair, depth computed from the stereo pair, and a 400 Hz IMU. Both hands wear custom sensor gloves under red work gloves. Each glove has 12 six-axis motion sensors (accelerometer plus gyroscope) on the back of the hand and the finger and thumb segments, and 10 force pads on the fingertips and palm, given as conductance and as estimated force in newtons. Each glove records at 200 Hz on its own clock, fitted to the camera's. From each glove's motion sensors the package adds a 21-joint 3D hand pose in MANO joint order, 21 joint angles, rotations for MANO's 15 finger joints in MANO's axis-angle layout and the hand's tilt for every frame, plus each hand's orientation in the camera frame and, wherever a forearm-pod tag is in view, the wrist's 3D position and the 21 joints in camera coordinates and image pixels. This listing's gallery has a one-minute showcase video (steps 36 and 37: marking a wire and stripping the feeder wires at the main panel) with both hands' force beside the video and each hand's skeleton drawn on the video wherever the forearm-pod tags place it.
## Contents
- Episode count: 38
- Total duration: 0.76 hours of capture (2,729 seconds), the same span in each episode's colour, left, right, depth and depth-confidence files
- Video files: 190 (38 colour, 38 left, 38 right, 38 depth, 38 depth confidence)
- Total frames: 409,370 across the 190 video files (81,874 each for colour, left, right, depth and depth confidence)
- Total size: 23.34 GB
- Frame rate: 30 fps
- Audio: not included
- IMU: accelerometer and gyroscope at 400 Hz (the camera's built-in IMU)
- IMU log: imu/episode_NNNNNN.imu.jsonl, one per episode, named after its video clips; each line holds t_us (microseconds from the episode's first video frame, device clock), acc [x, y, z] in m/s2, gyro [x, y, z] in rad/s, and acc_t_us for the accelerometer reading paired with that gyroscope sample
- IMU in the LeRobot data: observation.imu, 6 values per frame at 30 Hz (accelerometer in m/s2 with gravity, gyroscope in rad/s), interpolated to each colour frame's device time
- Raw IMU: capture/episode_NNNNNN/imu.parquet, the same 400 Hz samples with device and host timestamps and sequence numbers
- Format: LeRobot v2.1 (loads with `LeRobotDataset`), plus a sidecar folder `capture/` with the raw sensor streams
- Licence: non-exclusive commercial licence; use is governed by the Data Licence Agreement accepted at purchase
## Streams
| Stream | Files | Resolution | Frame rate | Codec | Audio | Type |
|--------|-------|------------|------------|-------|-------|------|
| colour | videos/chunk-000/observation.images.colour/episode_*.mp4 | 2016x1520 | 30 fps | AV1 | not included | wide-angle |
| left | videos/chunk-000/observation.images.left/episode_*.mp4 | 640x400 | 30 fps | AV1 | not included | stereo |
| right | videos/chunk-000/observation.images.right/episode_*.mp4 | 640x400 | 30 fps | AV1 | not included | stereo |
| depth | videos/chunk-000/observation.images.depth/episode_*.mp4 | 504x380 | 30 fps | HEVC, lossless 12-bit | not included | depth |
| depth confidence | videos/chunk-000/observation.images.depth_confidence/episode_*.mp4 | 504x380 | 30 fps | AV1 | not included | depth confidence |
The left and right files are the two views of the global-shutter stereo pair (7.5 cm baseline), grey stored as 3 equal channels, one file per eye. The colour video is wide-angle and not undistorted. Depth is millimetres along the colour camera's optical axis, lined up with the colour frame at a quarter of its size, 0 where there is none; LeRobot stores it as a lossless 12-bit log-scaled video and returns it in mm. It was computed after recording from the raw stereo pair (OpenCV semi-global matching run both ways, kept where the two agree), so it reaches no nearer than about 0.17 m and bare walls get little of it (the camera's infrared dot projector was off). Depth confidence is how sure the matcher was of each pixel, 1–255, 0 where there is no depth. meta/info.json has the depth grid's intrinsics and lens model.
## Sensor data
| Data | Where | Rate | Units / format |
|------|-------|------|----------------|
| head IMU | imu/episode_NNNNNN.imu.jsonl; data: observation.imu; raw: capture/episode_NNNNNN/imu.parquet | 30 Hz in data, about 400 Hz in the log and raw | accelerometer m/s2 (gravity included), gyroscope rad/s |
| left glove motion sensors | data: observation.hand.left.imu; raw: capture/episode_NNNNNN/hand_left.parquet | 30 Hz in data, 200 Hz raw | 12 boards x (accelerometer m/s2, gyroscope rad/s), each in its own axes |
| left glove force pads | data: observation.hand.left.pads; raw: hand_left.parquet | 30 Hz in data, 200 Hz raw | 10 pads, conductance in microsiemens (rises with force); raw 12-bit ADC counts |
| left glove pad force | data: observation.hand.left.pad_force | 30 Hz | 10 pads, estimated force in newtons from bench curves (see Accuracy and error margins) |
| left glove validity | data: observation.hand.left.valid | 30 Hz | 1 where each board and the pads have a reading |
| left 3D hand pose | data: observation.hand.left.keypoints_3d | 30 Hz | 21 joints x (x, y, z) in metres, hand frame, MANO joint order |
| left joint angles | data: observation.hand.left.joint_angles | 30 Hz | 21 named angles in radians |
| left joint rotations | data: observation.hand.left.joint_rotations | 30 Hz | MANO's 15 finger joints x axis-angle (rx, ry, rz) in radians, MANO order |
| left hand tilt | data: observation.hand.left.palm_up | 30 Hz | unit "up" vector in the hand frame |
| left wrist position | data: observation.hand.left.wrist_position | 30 Hz | x, y, z in metres, colour camera frame (where the pod tags give it) |
| left hand orientation | data: observation.hand.left.wrist_rotation | 30 Hz | quaternion (x, y, z, w), hand frame to colour camera frame |
| left 3D hand pose in camera | data: observation.hand.left.keypoints_cam | 30 Hz | 21 joints x (x, y, z) in metres, colour camera frame, MANO joint order |
| left 2D hand keypoints | data: observation.hand.left.keypoints_2d | 30 Hz | 21 joints x (u, v) in colour-image pixels |
| left wrist pose source | data: observation.hand.left.wrist_pose_source | 30 Hz | 2 tag seen, 1 interpolated, 0 no position |
| right glove motion sensors | data: observation.hand.right.imu; raw: capture/episode_NNNNNN/hand_right.parquet | 30 Hz in data, 200 Hz raw | 12 boards x (accelerometer m/s2, gyroscope rad/s), each in its own axes |
| right glove force pads | data: observation.hand.right.pads; raw: hand_right.parquet | 30 Hz in data, 200 Hz raw | 10 pads, conductance in microsiemens (rises with force); raw 12-bit ADC counts |
| right glove pad force | data: observation.hand.right.pad_force | 30 Hz | 10 pads, estimated force in newtons from bench curves (see Accuracy and error margins) |
| right glove validity | data: observation.hand.right.valid | 30 Hz | 1 where each board and the pads have a reading |
| right 3D hand pose | data: observation.hand.right.keypoints_3d | 30 Hz | 21 joints x (x, y, z) in metres, hand frame, MANO joint order |
| right joint angles | data: observation.hand.right.joint_angles | 30 Hz | 21 named angles in radians |
| right joint rotations | data: observation.hand.right.joint_rotations | 30 Hz | MANO's 15 finger joints x axis-angle (rx, ry, rz) in radians, MANO order |
| right hand tilt | data: observation.hand.right.palm_up | 30 Hz | unit "up" vector in the hand frame |
| right wrist position | data: observation.hand.right.wrist_position | 30 Hz | x, y, z in metres, colour camera frame (where the pod tags give it) |
| right hand orientation | data: observation.hand.right.wrist_rotation | 30 Hz | quaternion (x, y, z, w), hand frame to colour camera frame |
| right 3D hand pose in camera | data: observation.hand.right.keypoints_cam | 30 Hz | 21 joints x (x, y, z) in metres, colour camera frame, MANO joint order |
| right 2D hand keypoints | data: observation.hand.right.keypoints_2d | 30 Hz | 21 joints x (u, v) in colour-image pixels |
| right wrist pose source | data: observation.hand.right.wrist_pose_source | 30 Hz | 2 tag seen, 1 interpolated, 0 no position |
## The gloves
Motion sensors on each glove (Bosch BMI160, accelerometer plus gyroscope only): H0 back of the hand; T0 thumb metacarpal, T1 thumb proximal, T2 thumb distal; I0/I1 index proximal/middle; M0/M1 middle proximal/middle; R0/R1 ring proximal/middle; L0/L1 little proximal/middle.
Force pads on each glove (force-sensing resistors): F0 thumb pad, F1 index tip, F2 middle tip, F3 ring tip, F4 little tip, P0 thenar, P1 hypothenar, P2 distal palm, P3 central palm, P4 index-base palm. Every pad is an Interlink FSR UX 400 force-sensing resistor (14.68 mm active area). `.pads` gives each pad's conductance (1 / resistance) in microsiemens, about 0.1 to 0.2 untouched and rising with force. `.pad_force` converts each 200 Hz sample to newtons through a force-versus-conductance curve, then takes it to the frame like the other glove streams. The curves (dated 2026-11-05) were refit from load-cell bench runs on the right glove's pads before they were sewn in; P4 uses Interlink's published FSR 400 curve. The raw ADC counts are kept, so newtons can be recomputed whenever a pad is recalibrated. These newtons are estimates; see Accuracy and error margins.
- Right glove: all 12 boards report in every frame. No samples were lost. The index-tip pad (F1) and middle-tip pad (F2) barely respond in this recording (contact in 0.2% and 0.2% of frames), so right index and middle fingertip contact is mostly not captured. The thenar pad (P0) reads a steady load for most of the recording (66% of frames above 0.02 N), most likely the glove pressing on it, so its absolute newtons are unreliable; it is also the one pad that reaches the top of its curve (50 N, where the value is held) in about 1.1% of the glove's samples.
- Left glove: the ring proximal board (R0) has a reading in only 1.8% of frames; the other 11 boards report in every frame. The glove lost 60 of about 649,000 samples in 51 short gaps (interpolated across in the data; the raw file keeps the gaps). All 10 pads respond. The left pads have no bench curves of their own: their newtons use the same curves as the right glove's pads, so treat left-hand newtons as rougher than the right's.
## Hand pose (derived from the gloves)
observation.hand.{left,right}.keypoints_3d hold 21 joints per frame in the MANO joint order used by MANO-based hand datasets: wrist; index 1-3; middle 1-3; little 1-3; ring 1-3; thumb 1-3; then the thumb, index, middle, ring and little fingertips. `meta/info.json` also lists the indices that reorder them into the OpenPose / MediaPipe 21-keypoint order. Coordinates are in metres in each hand's own frame: origin at the wrist, y toward the fingertips along the palm, z out of the back of the hand, x = y cross z (toward the little finger on the right hand, toward the thumb on the left hand; right-handed on both).
How it is made: each motion sensor's orientation is estimated from its accelerometer and gyroscope (Mahony filter at 200 Hz, run once through each glove's whole session). Without a compass, each sensor's heading drifts on its own; the drift between neighbouring segments is removed with joint constraints (finger PIP and thumb IP joints as hinges, MCP and thumb CMC joints as two-axis joints). Each segment then takes the orientation of its sensor, and a standard adult hand template supplies the bone lengths and knuckle positions. joint_angles gives MCP flexion and abduction, PIP flexion and the estimated DIP flexion for each finger, and the thumb's CMC (three angles), MCP and IP flexion. palm_up gives the hand's tilt relative to gravity.
joint_rotations follows MANO's pose layout as closely as possible without the MANO model: 45 values per hand, MANO's 15 finger joints in MANO order (index 1-3, middle 1-3, little 1-3, ring 1-3, thumb 1-3), each the axis-angle rotation of the bone that joint drives relative to its parent bone, with every joint frame aligned to the hand frame in the flat rest pose (the MANO/SMPL convention, so a bone's rotation from rest is the product of the local rotations down its chain). To use them as MANO hand_pose, express each vector in MANO's template axes (one fixed rotation from this hand frame) and, for MANO with flat_hand_mean=False, subtract MANO's mean pose. The wrist's own rotation is wrist_rotation. The four DIP rotations come from the estimated DIP angles.
Right glove mounting calibration: the right glove's back-of-hand and finger sensors use a measured mounting calibration (how each board sits on its segment, plus each gyro's bias) from a calibration session on 4 November 2026 with a different wearer. The thumb's metacarpal and proximal boards failed that session's mounting test and keep the nominal mounting. With the calibration, the right MCP abduction angles centre near zero; with the nominal mounting they rested at the joint limit in up to half of the frames. The left glove had no calibration session and uses the nominal mounting.
What it is not:
- Not fitted MANO parameters. The joints are in MANO's order so they drop into MANO fitting and retargeting pipelines, but no MANO model files or MANO pose/shape parameters are included. Buyers with a MANO licence can fit it to these joints.
- Bone lengths are a template, not measured on this wearer, and the four fingers' distal (DIP) joints have no sensor (set to 2/3 of the PIP flexion).
- Left ring finger: where R0 has no reading (about 98% of frames) the left middle proximal sensor stands in for it, so the left ring MCP follows the middle finger and the left ring PIP is measured against that.
### Hand position and orientation in the camera
Each glove has a pod strapped to the back of the forearm just behind the wrist, carrying two AprilTags (tag36h11): a 40 mm tag on the pod top and a 20 mm tag on a side face, at right angles. The tags are found in the colour video, each tag's pose comes from its four corners and the camera calibration (IPPE), and the pod's two tags are combined using their fixed relative pose (measured from this recording: 90.6 deg, 35.5 mm on the left pod, 90.4 deg, 35.2 mm on the right; a separate calibration take gave 89.6 deg / 37.1 mm and 90.0 deg / 35.1 mm). The wrist joint centre sits at a fixed offset from the pod (fitted on that calibration take: about 100 mm toward the hand and 70 mm below the top tag on the left, 74 mm and 80 mm on the right), which gives wrist_position.
The pod tracks the forearm, not the hand, so the hand's orientation (wrist_rotation) is built from the gloves: its tilt comes from gravity, measured by the glove's back-of-hand sensor and by the head camera's IMU on every frame; its heading relative to the camera comes from the two gyros, and is pinned to the forearm pod whenever a tag is seen (the wrist is assumed to have no twist relative to the forearm while flexion and side-to-side deviation stay free), smoothed over about 4 seconds. keypoints_cam = wrist_position + wrist_rotation applied to keypoints_3d, and keypoints_2d projects them into the colour image with its lens model.
| Hand | Frames with a pod tag seen | Frames with a wrist position (tag or gap of 0.33 s or less) | Frames with hand orientation |
|------|----------------------------|------------------------------------------------------------|------------------------------|
| left | 27% | 32% | 100% |
| right | 13% | 17% | 100% |
When the hands are out of the camera's view, or the pod faces away, there is no position; wrist_rotation is still given on every frame the glove records.
## Accuracy and error margins
Nothing in this dataset has been checked against a reference instrument during the job: there was no load cell inside the gloves and no motion capture on the hands. Rely on when contact happens, which pad is loaded and how force rises and falls. Treat absolute newtons and absolute joint angles as approximate.
### Force in newtons (pad_force)
Rule of thumb: a single reading could be off by about a third to a half, so a 2 N reading may really be anywhere from about 1 to 3 N. That is a rough guide drawn from the bench numbers below, not a measured error bar. The ring-tip curve (F3), the left glove (borrowed curves), the right thenar pad (preload) and anything under about 0.4 N are less certain than that.
- Hysteresis: the same force reads differently while pressing and while releasing; on the bench the two differed by 27 to 52% per pad (target 10% or less; every pad missed it).
- Repeatability: repeating the same press gave a spread of 6.6 to 28.5% on most pads and 80.2% on the ring tip (target 5% or less).
- Drift: under a steady held load three pads rose 8.3 to 14.2% in about 5 minutes (target 8% or less).
- Range: each curve was measured from about 0.3 to 0.4 N up to 20 to 39 N; beyond that the curve is extrapolated. Light touches often fall below the bottom of the range.
- Not in these numbers: the curves were measured on the bare sensor stack before the pads were sewn in. The glove fabric, the pad cover, the work glove on top and the curve of the finger all change how force reaches a sensor; that effect has not been measured and comes on top of the figures here.
- Curve fit: each bench curve follows its own bench presses with a median error of 6 to 11% and a 90th-percentile error of 22 to 35%, on top of the hysteresis, repeatability and drift above.
- P4 (index-base palm, both gloves) has no bench run; its newtons use Interlink's published FSR 400 curve (typical part, digitized from the datasheet graph), so P4 is the least certain pad.
Right glove (bench curves measured on these pads):
| Pad | Hysteresis | Repeatability spread | Drift under held load | Measured range | Frames in contact | Contact frames below range | Contact frames above range | Highest force here |
|-----|------------|----------------------|-----------------------|----------------|-------------------|----------------------------|----------------------------|--------------------|
| F0 thumb pad | 37.0% | passed | passed | 0.40–33 N | 4.1% | 10% | 0.0% | 14.1 N |
| F1 index tip | 30.0% | 13.7% | passed | 0.40–32 N | 0.2% | 47% | 0.0% | 2.9 N |
| F2 middle tip | 38.9% | 28.5% | +14.2% in 328 s | 0.40–30 N | 0.2% | 71% | 0.0% | 3.3 N |
| F3 ring tip | 32.6% | 80.2% | passed | 0.40–34 N | 11.8% | 39% | 0.0% | 12.0 N |
| F4 little tip | 45.6% | 15.8% | +9.6% in 330 s | 0.40–35 N | 7.7% | 25% | 0.0% | 22.3 N |
| P0 thenar | 26.9% | 20.4% | passed | 0.40–57 N | 65.8% | 18% | 0.0% | 50.0 N |
| P1 hypothenar | 28.0% | 21.3% | passed | 0.40–54 N | 15.9% | 36% | 0.0% | 11.2 N |
| P2 distal palm | 32.7% | 6.6% | passed | 0.40–43 N | 4.1% | 52% | 0.0% | 7.1 N |
| P3 central palm | 52.2% | 14.6% | +8.3% in 315 s | 0.40–46 N | 13.2% | 32% | 0.0% | 10.2 N |
| P4 index-base palm | no bench run | no bench run | no bench run | 0.25–19 N | 27.3% | 21% | 0.0% | 2.4 N |
Left glove (no bench run of its own; the same curves as the right glove are applied):
| Pad | Hysteresis | Repeatability spread | Drift under held load | Measured range | Frames in contact | Contact frames below range | Contact frames above range | Highest force here |
|-----|------------|----------------------|-----------------------|----------------|-------------------|----------------------------|----------------------------|--------------------|
| F0 thumb pad | 37.0% | passed | passed | 0.40–33 N | 21.2% | 7% | 0.0% | 21.2 N |
| F1 index tip | 30.0% | 13.7% | passed | 0.40–32 N | 24.7% | 32% | 0.0% | 24.8 N |
| F2 middle tip | 38.9% | 28.5% | +14.2% in 328 s | 0.40–30 N | 34.5% | 38% | 0.0% | 30.0 N |
| F3 ring tip | 32.6% | 80.2% | passed | 0.40–34 N | 29.8% | 36% | 0.0% | 29.6 N |
| F4 little tip | 45.6% | 15.8% | +9.6% in 330 s | 0.40–35 N | 6.2% | 24% | 0.0% | 13.5 N |
| P0 thenar | 26.9% | 20.4% | passed | 0.40–57 N | 58.2% | 45% | 0.0% | 10.5 N |
| P1 hypothenar | 28.0% | 21.3% | passed | 0.40–54 N | 20.0% | 29% | 0.0% | 13.8 N |
| P2 distal palm | 32.7% | 6.6% | passed | 0.40–43 N | 23.4% | 23% | 0.0% | 9.8 N |
| P3 central palm | 52.2% | 14.6% | +8.3% in 315 s | 0.40–46 N | 9.5% | 44% | 0.0% | 3.9 N |
| P4 index-base palm | no bench run | no bench run | no bench run | 0.25–19 N | 37.0% | 31% | 0.0% | 2.3 N |
Contact frames are frames above 0.02 N. Bench targets: hysteresis 10%, repeatability 5%, drift 8% in 5 minutes. meta/info.json lists each pad's bench run and failed checks.
### Timing
- Camera to camera: the stereo pair is hardware-synced to the colour camera, matched within 0.05 ms in 99% of frames; in episode 3 of the full recording two stereo frames were replaced by their neighbours (frames.parquet flags them).
- Right glove to camera: no clock link this session, so its clock is fitted to the camera from the glove's start-up light flashes and 30-second marks seen in the colour video (1.3 ms RMS residual; each anchor good to about 13 ms). Its clock drift was checked over the whole session against the head camera: 8.6 ms scatter.
- Left glove to camera: timed from 1,615 clock-exchange pairs (0.5 ms uncertainty); its start-up flashes seen in the colour video agree within 6 ms, under a frame.
### Hand pose (keypoints_3d, joint_angles, palm_up)
- Not yet compared against motion capture or another reference, so there is no measured error figure.
- Absolute joint angles: expect offsets of up to about 10 degrees (the left glove has no mounting calibration, and the right glove's comes from a different wearer). Changes in angle (grasp timing, finger motion) are more reliable than absolute angles; MCP abduction and the thumb CMC angles are the least reliable.
- Wrist position: not compared with a reference. The tag poses agree with each other on a pod to about 2 degrees, and when the wrist is drawn on the video it lands on the red work glove in 85 to 96% of checked frames (400 frames from 16 episodes); the pod-to-wrist offset is a fixed fit, so wrist bending moves the true wrist centre by up to about 1 to 2 cm from it.
- Hand heading relative to the camera: the per-sighting estimates scatter around the smoothed value by a median of 8 degrees (left) and 9 degrees (right); between sightings it rests on the gyros. Tilt comes from gravity and is better than heading.
- As a consistency check, the same method was re-run on our earlier two-lights recording and compared with the pose shipped with it: PIP flexion agreed with a correlation of 0.77 to 0.98 and joint positions differed by 15 mm on average.
## Steps
| Episode | Source step | Starts (into this package) | Length | Step |
|---------|-------------|----------------------------|--------|------|
| 0 | 0 | 0:00 | 81 s | open the main panel's door, unscrew and lift off its dead front, and look inside |
| 1 | 1 | 1:21 | 63 s | walk to the subpanel's spot along the wall and sort out the wire coils, conduit and fittings there |
| 2 | 2 | 2:24 | 39 s | pull a black wire off its coil and walk it along the side yard to the main panel to measure the run |
| 3 | 3 | 3:03 | 113 s | pull more black wire off the coils at the wall (the goats get in the way) |
| 4 | 4 | 4:56 | 56 s | carry a bundle of black wire along the side yard to the main panel, laying it out |
| 5 | 5 | 5:52 | 92 s | unwind the rest of the black wire coil at the wall |
| 6 | 6 | 7:24 | 55 s | carry the black wires toward the main panel and lay them out |
| 7 | 7 | 8:19 | 63 s | pull the green ground wire off its coil and lay it out beside the black ones |
| 8 | 8 | 9:22 | 55 s | check the conduit stub at the wall, then walk to the main panel to look and come back |
| 9 | 9 | 10:17 | 67 s | get tools and fittings out of the bag at the conduit stub (screwdriver, drill) |
| 10 | 10 | 11:24 | 30 s | cut a piece of conduit with the band saw |
| 11 | 11 | 11:54 | 160 s | mark the wire ends with red and white tape |
| 12 | 12 | 14:34 | 153 s | push the taped wire bundle into the conduit at the wall |
| 13 | 13 | 17:07 | 107 s | walk to the main panel to see whether the wires came through, push more in at the wall, and go back |
| 14 | 14 | 18:54 | 33 s | pull the wires up into the bottom of the main panel |
| 15 | 15 | 19:27 | 94 s | pull the wires on through into the main panel and route them |
| 16 | 16 | 21:01 | 41 s | walk back to the wall and check the wire ends at the conduit stub |
| 17 | 17 | 21:42 | 50 s | unbox the new subpanel and carry it to the pallet |
| 18 | 18 | 22:32 | 61 s | open the subpanel's cover and take out its paperwork |
| 19 | 19 | 23:33 | 53 s | get the drill and take the subpanel's dead front off |
| 20 | 20 | 24:26 | 47 s | get a conduit adapter and knock out a hole in the subpanel's bottom |
| 21 | 21 | 25:13 | 86 s | fit the adapter into the knockout, tighten its locknut, and hold the subpanel up to the wall |
| 22 | 22 | 26:39 | 89 s | slide a coupling and a length of conduit over the wires onto the stub |
| 23 | 23 | 28:08 | 52 s | cut the conduit to length with the band saw, twice |
| 24 | 24 | 29:00 | 63 s | fit the cut conduit and fittings onto the stub at the corner |
| 25 | 25 | 30:03 | 60 s | walk to the main panel to look, then cut another piece of conduit with the band saw |
| 26 | 26 | 31:03 | 47 s | fit the new piece, then walk to the main panel to look again |
| 27 | 27 | 31:50 | 67 s | glue the conduit pieces with PVC cement and slide them over the wires |
| 28 | 28 | 32:57 | 32 s | walk to the main panel, then cut a piece of conduit with the ratchet cutter |
| 29 | 29 | 33:29 | 48 s | fit the cut conduit and a coupling over the wires on the wall |
| 30 | 30 | 34:17 | 47 s | get straps and screws from the tool bag |
| 31 | 31 | 35:04 | 82 s | carry the subpanel to the wall, thread the wires into it and set it on the conduit |
| 32 | 32 | 36:26 | 99 s | level the subpanel and screw it to the wall |
| 33 | 33 | 38:05 | 80 s | strap the conduit to the wall and recheck the level |
| 34 | 34 | 39:25 | 112 s | connect the feeder wires in the subpanel |
| 35 | 35 | 41:17 | 114 s | walk to the main panel and route the feeder wires inside it |
| 36 | 36 | 43:11 | 56 s | mark a wire with white tape at the main panel |
| 37 | 37 | 44:07 | 82 s | strip the feeder wires and start connecting them in the main panel (the recording stops mid-step) |
## Layout
- meta/: info.json (features, with units, frames and method notes for the glove and hand-pose features, and each force pad's bench curve source), episodes.jsonl (each episode's step and step label), tasks.jsonl (one task string per step), episodes_stats.jsonl
- data/chunk-000/episode_NNNNNN.parquet: one row per frame with every observation above, timestamp and indices
- videos/chunk-000/observation.images.{colour,left,right,depth,depth_confidence}/episode_NNNNNN.mp4
- imu/episode_NNNNNN.imu.jsonl: the head IMU log for each episode, named after its video clips
- capture/episode_NNNNNN/: meta.json (capture settings), calibration.json (camera factory calibration: intrinsics, distortion, and extrinsics between the cameras and the IMU), frames.parquet (per-frame source numbers, device, host and Unix times, exposure, ISO, colour temperature, stereo offsets), imu.parquet (head IMU at full rate), hand_left.parquet and hand_right.parquet (each glove at the full 200 Hz in raw counts, with the fractional dataset frame of each sample), hand_left.json and hand_right.json (glove session, clock fit, events, column notes)
- capture/export.json: each episode's source recording, step boundaries and export settings
- README.md: this card
## Capture hardware
- Head camera: Luxonis OAK-D Pro W, head-mounted, mounted upside down (all three image streams are turned 180 degrees from calibration.json's camera frames; see each meta.json)
- Colour sensor: Sony IMX378, rolling shutter, 120 degrees diagonal field of view, auto exposure capped at 8.3 ms, auto white balance, lossless capture re-encoded to AV1 for this export
- Stereo sensors: two OmniVision OV9282 global-shutter cameras, 7.5 cm baseline, 150 degrees diagonal field of view, IR dot projector and flood light off
- Head IMU: on the camera board, accelerometer 480 Hz and gyroscope 400 Hz raw
- Gloves: custom sensor gloves on both hands, each with 12 BMI160 boards (accelerometer 2048 counts per g, gyroscope 16.4 counts per degree per second) and 10 force-sensing pads read by a 12-bit ADC, 200 Hz, recording to the pod on the wrist
## Timing
- Colour frame sequence numbers are continuous within every episode; no colour frame was dropped, replaced or duplicated
- Every frame has head IMU data in range
- Both gloves cover every frame (one glove session each for the whole job)
## Task and environment
- Task: outdoor electrical conduit installation at a home: feeder wires from the main panel through PVC conduit to a new subpanel on the outside wall; each episode's task string adds its step
- Environment: outdoors, in daylight, along the side of a house: the main panel and meter, a concrete side yard, the wall where the subpanel goes, a tool bag and pallet; two goats wander through some steps
- Operator: one master electrician, wearing a sensor glove under a red work glove on each hand
- Activity: continuous work, including tool use (drill, screwdrivers, band saw, ratchet cutter, level), fine manipulation (taping and stripping wires, locknuts, terminations), bimanual holding and carrying, and walking between work sites
## Privacy
One other person, a helper, appears in parts of the job. Their face and head are blurred in the colour and both stereo videos wherever they appear. They were found frame by frame with face, body-pose and person detection, mapped between the cameras through the calibration, and checked by eye. The same regions are set to no depth in the depth video and blurred in depth confidence. The electric meter's ID number and barcode, a serial number on a bin and long printed numbers on labels are blurred wherever readable. No audio is included. The setup inside the house and the walk out past parked vehicles were cut before export.
## Known limitations
- No audio
- Right glove: index-tip (F1) and middle-tip (F2) pads barely respond; the thenar pad (P0) carries a steady preload
- Left glove: ring proximal motion sensor (R0) mostly missing; pads use the right glove's bench curves
- Force in newtons is an estimate from bench curves measured before the pads were sewn in, not an in-glove load-cell calibration
- Hand pose is computed from the gloves' motion sensors as described above: template bone lengths, estimated DIP joints; the wrist position in the camera is only given where a forearm-pod tag is in view
- Both hands wear red work gloves over the sensor gloves; each glove's forearm pod (with two printed AprilTags, used for the wrist position) is visible on the wrist
- The wide-angle frames are not undistorted; depth comes from passive stereo, so it is sparse on plain walls and absent closer than about 0.17 m
- The recording stops mid-step in the last step of the job (the recorder's disk filled)
- One electrician at one site
This is not an openly licensed dataset: use is governed by the Data Licence Agreement accepted at purchase.